POLAROOF AC is a premium quality, acrylic, single component waterproofing coating.  Designed for permanent flexibility and toughness, POLAROOF AC provides a finish that is architecturally enhancing, long-lasting, and weatherproof.

 

    

OUTSTANDING FEATURES:

               

§         Provides long lasting waterproofing protection

§         Performs on all standard roofing substrates

§         Environmentally friendly (contains no solvents)

§         Inhibits corrosion

§         Resists fungal attack

§         Can easily be recoated without use of primer

§         Remains flexible, tough, and weatherproof in all climates

§         Will not get brittle and crack with age

§         Protects against UV deterioration

§         Ten year material warranty

POLAROOF AC is a premium quality, waterproof, tough, elastic coating with unique properties that extend the lifespan of most roofs.  The technology behind the formulation of this material uses acrylic chemistry and advanced mineral design to create a composite coating that forms a shield to protect against water penetration, corrosion, and stress fatigue from thermal cycling.  Long-term waterproofing is maintained by tenacious adhesion to the substrate and flexibility over a wide temperature range without cracking at low temperatures or melting or flowing at high temperatures. The hydrophobic nature of the mineral structure within the composite forms a barrier to prevent the ion transfer that characterizes corrosion.  Additionally, the ability to suppress stress fatigue by absorbing the heat energy and conversion through endothermic reaction will significantly enhance the longevity of the roof structure.

OUTSTANDING FEATURES

 Reduces stress fatigue due to thermal cycling

 Available in a wide range of standard and custom colors

 Carries the highest U.L. rating for fire protection at unlimited slope

 EPA Energy Star rating reassures significant energy savings

 May be combined with I.F. reflecting basecoat to lower B.T.U. consumption

 Very fast setting to prevent wash-off

 Completely dry surface remains clean

 Provides long lasting waterproofing protection

 Performs on all standard roofing substrates

 Environmentally friendly (contains no solvents)

 Inhibits corrosion

 Resists fungal attack

 Can easily be recoated without use of primer

 Remains flexible, tough, and weatherproof in all climates

 Will not get brittle and crack with age

 Protects against UV deterioration

 Ten year material warranty

 May be recoated to last 20 or 30 years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS: 

Coating Type:     

Acrylic  elastomeric

VOC:  

10 grams/liter

Pot Life: 

Not applicable (single component)

Shelf Life:      

12 months unopened

Recommended Thickness:   

32 dry mils

Coverage:    

3 gallons per l00 square feet;  48 wet mils

Packaging:

5 gallons standard; 1 gallon and 55 gallon sizes available

Color:   

White, Black, Red, Green, Dark Gray, and Colonial Gray are standard. Other colors are available

EPA:

Complies with all existing regulations

 

APPLICATION:                                                                                                                                   

Caution!  READ THIS ENTIRE DATA SHEET BEFORE CONTINUING.   CONTINUING.                                                       

Surfaces must be dry, free of dirt, loose debris, oils, greases or any substance that could interfere with bond. All repairs of damage or defects must be made prior to application.                                                                                                         

Roofing Substrate Priming Requirements:                                                 

 

  Substrate      

  Primer

Asphalt or asbestos shingles, bituminous materials (BUR)

Polaprime 2

Painted metal or galvalume

Polaprime 4

Oxidized metal    

Polaprime 21

Polyurethane foam (PUF)  

Unnecessary

Slate, tile and concrete

Unnecessary

 

                             

Polaroof AC is an alkaline water-based product. Polaroof AC is applied straight out of the can after 2 minutes of gentle low speed mixing or stirring. Apply the product using brush, roller or spray technique.  Apply in two coats to a uniform wet film thickness of about 24 mils per coat to insure complete coverage on the 2nd coat. Apply the 2nd coat after the 1st coat has set (about 2-4 hours).  For spray applications, use a 30:1 ratio Graco with a #36 tip or similar equipment. For soft brush or high nap roller application, use light pressure and coat in a cross direction to the 1st coat. For additional information, contact our Technical Department. Department.                                                                                                                                       

LIMITATIONS:

Do not apply to frozen or saturated surfaces. Do not apply if the temperature is predicted to drop below 35°F within 4 hours after application is completed. Do not apply if rain is forecast within 4 hours of completion of application. Protect Polaroof AC from freezing.  In roofing areas where water is likely to pond and be present for more than 1 day after precipitation, it is advisable to topcoat the Polaroof AC with Clearcoat 44 or Clearcoat AQ. Apply the Clearcoat in these areas at the rate of 1 gallon per 200 square feet.

 

PRECAUTIONS:

Avoid contact with skin and eyes. In case of contact, immediately flush with water.  For eyes, get medical attention to flushing. Avoid inhalation of spray mist.  If spray mist is inhaled, seek immediate medical attention. In case of ingestion, immediately contact a physician. Wear rubber gloves, coveralls, and safety goggles when applying.

 

MAINTENANCE:

If a surface becomes dirty or stained, wash with a mild soapy water solution. If an area becomes nicked or cut, recoat with Polaroof AC. Clean tools and equipment with water before the Polaroof AC dries; after that, solvent cleaning may be necessary.

 

TECHNICAL DATA:

Moisture Vapor Transmission:    

3.5 perms

ASTM E-96

Tensile Strength:

250 psi

ASTM D-412

Elongation:

750%

ASTM D-412

Impact Resistance:      

4mm indent. pass

BS3900 Part E3

Solids:  

73% (B.W.), 67% (B.V.)ASTM D-1044

Flashpoint:

Non-flammable

Closed Cup

Weatherometer (5000 hours):

PassASTM G23

Fire Rating:

Class AASTM E108

Shore 'A' Hardness:

60 degreesASTM D2240

Viscosity:

7,000 cps 

Density:

Approx. 11.5 lbs/gal. 

pH:

9.0 

 

NOTICE:  The information presented herein is based on tests and data that Andek Corporation believes to be reliable.  It is intended for use by technically qualified personnel at their own discretion and risk.  Since conditions of handling and use are beyond our control, we make no warranties, express or implied, and assume no liability in connection with any use of this information.  Nothing herein is to be construed as a license to operate or a recommendation to infringe any patent.

 

 