Description
POLAGARD AG
High-Performance Anti-Graffiti Protective Coating
POLAGARD AG is a clear premium, high-performance aliphatic urethane coating engineered to cure into an extremely tough, durable, and long-lasting protective barrier. Designed for demanding public, commercial, and infrastructure environments, it provides superior resistance to graffiti, vandalism, weathering, chemical attack, and surface abrasion.
Once cured, POLAGARD AG forms a resilient, protective film that allows repeated graffiti removal without damaging the coating or underlying substrate. Its advanced formulation helps extend the service life of treated surfaces while maintaining long-term performance under heavy exposure conditions.
Designed to meet or exceed Department of Transportation requirements, POLAGARD AG is suitable for use on soundwalls, bridges, Jersey barriers, and other high-visibility infrastructure surfaces requiring maximum protection and durability.
Key Benefits
- Extreme Durability
Forms a tough, abrasion-resistant protective barrier for high-traffic and exposed environments - Anti-Graffiti Performance
Allows repeated removal of graffiti without damage to coating or substrate - Weather & Chemical Resistance
Protects against moisture, salt exposure, and chemical attack - Corrosion Protection
Contains corrosion-inhibiting components to protect metal substrates - Long-Term Flexibility
Resists embrittlement and maintains flexibility over time - Thermal Stability
Remains tough in cold temperatures and does not soften under high heat - Rapid Strength Development
Sets quickly and develops durable surface strength in a short time - Surface Protection & Preservation
Extends the effective service life of treated substrates - Easy Application
Can be applied by brush, roller, or airless spray - Fast Cleaning Capability
Facilitates quick removal of graffiti, dirt, soot, and contaminants
Recommended For
POLAGARD AG is suitable for use on a wide variety of substrates, including:
- Concrete
- Stucco
- Brick and masonry
- Mineral composites
- Fiberglass composites
- Structural steel and most metals
- EIFS (requires primer such as Polaprime 25)
- Porous and non-porous stone
- Wood and wood composites
- Industrial equipment and infrastructure
Coverage
Approximately 260 sq ft per gallon, depending on substrate and surface conditions.
Container sizes
3 gallon, 15 gallon
Technology
Aliphatic Urethane
Preparation and Application
Clear Finish Preparation
The substrate must be clean, dry, and free of loose particles, oils, or any substance that would interfere with adhesion. All repairs should be made prior to application of POLAGARD AG, and all repair materials must have completed setting or curing; otherwise, poor adhesion or discoloration may occur. E.I.F.S. and other materials that may be weakened by solvent exposure should be sealed with CLEARCOAT AQ. Concrete and all cementitious materials must be adequately cured (normally about 28 days).
Colored Finish Preparation
The substrate must be clean, dry, and free of loose particles, oils, or any substance that would interfere with adhesion. All repairs should be made prior to the application of POLAGARD AG, and all repair materials must have completed setting or curing; otherwise, poor adhesion or discoloration may occur. Metals should be primed with POLAPRIME 21. Wood and mineral composites should be primed with POLAPRIME 2. Other surfaces may need priming; refer to POLAPRIME data sheets for further information. Painted surfaces should be tested for compatibility. The best results may be obtained by complete removal of the paint without causing damage to the substrate. Some painted surfaces may require treatment with POLAPRIME 7 to prevent bleed-through or staining. After preparation is complete, a coat of WEARCOAT 44 should be applied at a rate of 200 square feet per gallon.
Application of Top Coats
POLAGARD AG Part A should be added to POLAGARD AG Part B and stirred thoroughly for 3 minutes using a mechanical, E.P. rated mixer. After the air bubbles from mixing have been released, the Polagard AG may be applied by brush, roller, or airless spray. Application to porous or highly textured surfaces may require two or three coats to obtain complete protection. Application over Wearcoat 44 is normally one single coat unless the surface is highly textured; then, two coats may be necessary. A minimum of 6 hours cure time is necessary prior to re-coating and a maximum of 72 hours shall be allowed for re-coating; otherwise, sanding, sweep blasting, or other surface abrasion may be necessary to obtain adequate intercoat adhesion.
Spray Application
For spray application use 30:1 airless pump, 1/2″ hose with 3/8″ whip and 35 to 41 tip
Recommended Thickness
2 coats yield 18 to 26 mils Dry Film Thickness (DFT)
Drying Time
Approximately 6 hours at 70°F (21°C) and 50% RH.
Cure Time
Approximately 72 hours at 70°F (21°C) and 50% RH.
Clean up
Clean tools and equipment with xylene or toluene solvent.
Limitations
Do not apply to frozen surfaces. Do not apply unless the temperature can be maintained above 40˚F for 8 hours. Surfaces must remain at least 5˚F above dewpoint during application and curing process. Application must be protected from precipitation for at least 4 hours. Do not contaminate product with moisture.
Maintenance
To remove graffiti, use environmentally approved cleaner to repair any damage to the coating system, call our Technical Department for assistance.
Storage
Store in a dry area and protect from direct sunlight and freezing. Keep container tightly sealed. Shelf life is 2 years from date of manufacture when stored in a factory sealed container between 40ºF (5ºC) and 90ºF (32ºC).
Disposal
Waste disposal must be in accordance with existing federal, state and local environmental control laws. Incineration is the preferred method of disposal.
Read the container label warning and Safety Data Sheet (SDS) for important health and safety information prior to the use of this product.
KEEP AWAY FROM CHILDREN AND PETS
For additional information, contact the Andek Technical Department
Technical Data
| VOC | 350 gms/liter | |
| Removal of Graffiti | Cleanability Level 1 | ASTM D-7089-06 |
| Flexibility at Low Temperature | 180 deg. bend @ 20°F | ASTM C-711 |
| Elongation Unsupported |
10% | ASTM D-412 |
| Tensile Strength | 3,000 psi | ASTM D-412 |
| Flashpoint | 105°F | FTMS 141A(M4293) |
| Solids Content |
68% (B.W.); 64% (B.V.) | ASTM D-1044 |
| Abrasion Resistance |
27 lt/mil | ASTM D-968-05 |
| Shore ‘A’ Hardness |
97 | ASTM D-2240 |
| Moisture Vapor Transmission | 1.84 gms/M2/24 hrs (=0.16 perms) | ASTM E-96 |
| Weatherometer (5000 hrs) | Pass | ASTM G-23 |
| Chemical Resistance | Passes 200 Mek Double Rubs | ASTM D-5402-06 |